Fire & Safety Performance

Fire Alarm Cable

INDOCABLES Fire Alarm Cables are designed for reliable signal transmission in fire detection, alarm, and emergency communication systems across commercial buildings, industrial…

Key Characteristics — Fire Alarm Cable

  • Fire Survival / Circuit Integrity
  • Low Smoke Zero Halogen (LSZH)
  • Flame Retardant & Flame Resistant
  • Heat Resistant
  • Interference-Free Signal Transmission
  • High Shielding Efficiency & Noise Immunity
  • Long Life (25+ Years)

ABOUT our Fire Alarm CABLES

INDOCABLES Fire Alarm Cables are designed for reliable signal transmission in fire detection, alarm, and emergency communication systems across commercial buildings, industrial facilities, hospitals, airports, metro stations, data centres, and critical infrastructure. Engineered for consistent electrical performance and enhanced fire safety, these cables ensure uninterrupted operation of fire alarm circuits, enabling early detection, rapid response, and safe evacuation during emergency situations.

Manufactured using high-purity copper conductors with premium-grade insulation systems, INDOCABLES fire alarm cables offer excellent signal integrity, flame retardance, low smoke emission, and zero halogen characteristics. Leveraging INDOCABLES’ in-house backward-integrated manufacturing capabilities, including proprietary high-grade mica tape production and precision taping processes, these cables achieve superior fire performance, controlled material quality, and consistent reliability. Available in shielded and unshielded constructions, these cables are suitable for indoor, outdoor, tray, duct, and conduit installations, ensuring dependable performance and compliance with applicable Indian and international fire safety standards.

Construction Overview

ParameterSpecification
Voltage Grade300 / 500 V
ConductorAnnealed Plain Stranded Copper / Annealed Tinned Copper
InsulationExtruded FR-LSZH / HFFR Polyolefin / PVC Type FRLS
Pairing / CablingTwisted Pairs / Multicore Cabling with Colour Identification
Flame BarrierMica Glass Flame Barrier Tape (optional – for fire resistant fire alarm cables)
ScreeningOverall Aluminium / Mylar (Al/PET) Tape Screen with Tinned Copper Drain Wire
Inner SheathExtruded LSZH / HFFR Polyolefin / PVC Type FRLS
ArmouringGalvanized Steel Round Wire Armour / Galvanized Steel Flat Strip Armour (optional)
Outer SheathExtruded LSZH / HFFR Polyolefin / PVC Type FRLS

Range — Fire Alarm Cable

1.5 – 400 sq.mm
Core: 2 – 37
Pair: 1, 2, 5, 10, 15, 20

Range — Fire Alarm Cable

CABLES FOR Fire Alarm Cable