Fire & Safety Performance
Fire Alarm Cable
INDOCABLES Fire Alarm Cables are designed for reliable signal transmission in fire detection, alarm, and emergency communication systems across commercial buildings, industrial…
Key Characteristics — Fire Alarm Cable
Fire Survival / Circuit Integrity
Low Smoke Zero Halogen (LSZH)
Flame Retardant & Flame Resistant
Heat Resistant
Interference-Free Signal Transmission
High Shielding Efficiency & Noise Immunity
Long Life (25+ Years)
ABOUT our Fire Alarm CABLES
INDOCABLES Fire Alarm Cables are designed for reliable signal transmission in fire detection, alarm, and emergency communication systems across commercial buildings, industrial facilities, hospitals, airports, metro stations, data centres, and critical infrastructure. Engineered for consistent electrical performance and enhanced fire safety, these cables ensure uninterrupted operation of fire alarm circuits, enabling early detection, rapid response, and safe evacuation during emergency situations.
Manufactured using high-purity copper conductors with premium-grade insulation systems, INDOCABLES fire alarm cables offer excellent signal integrity, flame retardance, low smoke emission, and zero halogen characteristics. Leveraging INDOCABLES’ in-house backward-integrated manufacturing capabilities, including proprietary high-grade mica tape production and precision taping processes, these cables achieve superior fire performance, controlled material quality, and consistent reliability. Available in shielded and unshielded constructions, these cables are suitable for indoor, outdoor, tray, duct, and conduit installations, ensuring dependable performance and compliance with applicable Indian and international fire safety standards.
Construction Overview
| Parameter | Specification |
|---|---|
| Voltage Grade | 300 / 500 V |
| Conductor | Annealed Plain Stranded Copper / Annealed Tinned Copper |
| Insulation | Extruded FR-LSZH / HFFR Polyolefin / PVC Type FRLS |
| Pairing / Cabling | Twisted Pairs / Multicore Cabling with Colour Identification |
| Flame Barrier | Mica Glass Flame Barrier Tape (optional – for fire resistant fire alarm cables) |
| Screening | Overall Aluminium / Mylar (Al/PET) Tape Screen with Tinned Copper Drain Wire |
| Inner Sheath | Extruded LSZH / HFFR Polyolefin / PVC Type FRLS |
| Armouring | Galvanized Steel Round Wire Armour / Galvanized Steel Flat Strip Armour (optional) |
| Outer Sheath | Extruded LSZH / HFFR Polyolefin / PVC Type FRLS |
Range — Fire Alarm Cable
1.5 – 400 sq.mm
Core: 2 – 37
Pair: 1, 2, 5, 10, 15, 20

CABLES FOR Fire Alarm Cable